SAIDY LICETH VASCONEZ NOGUERA

(Fonte: Lattes)
Índice h a partir de 2011
3
Projetos de Pesquisa
Unidades Organizacionais
LIM/49 - Laboratório de Protozoologia, Hospital das Clínicas, Faculdade de Medicina

Resultados de Busca

Agora exibindo 1 - 9 de 9
  • article 1 Citação(ões) na Scopus
    Case Report: Successful Treatment of Recurrent Urinary Tract Infection Due to Extensively Drug-Resistant Klebsiella Pneumoniae in a Kidney Transplant Recipient Using Chloramphenicol
    (2023) NETO, Lauro Vieira Perdigao; MACHADO, Anna Silva; SILVA, Riberto Garcia da; SOUZA, Ricardo Barbosa Cintra de; COUTINHO, Saurus Mayer; COMELLO, Florencia; PORTO, Ana Paula Matos; LIMA, Daila Sousa; GIOIA, Thais Sabato Romano di; LIMA, Victor Augusto Camarinha Castro; FARIAS, Luis Arthur Brasil Gadelha; MACEDO, Mariana Rolim Fernandes; NOGUERA, Saidy Liceth Vasconez; ANJOS, Sandra Nascimento dos; TONHEIRO, Chayenne Mika Matsumoto Pinto; COCENTINO, Brunno Cesar Batista; COSTA, Silvia Figueiredo; OLIVEIRA, Maura Salaroli de
    Effective therapies for multidrug-resistant (MDR) microorganisms, especially Gram-negative bacteria, are becoming rare. Also, solid-organ transplant recipients are at high risk of MDR Gram-negative bacilli infection. Urinary tract infections are the most frequent bacterial infections in kidney transplant recipients and are an important cause of mortality after renal transplantation. We describe a case of complicated urinary tract infection in a kidney transplant patient due to extensively drug-resistant (XDR) K. pneumoniae treated successfully with a regimen comprising a combination of chloramphenicol and ertapenem. We do not recommend chloramphenicol as a first-line choice for treating complicated urinary tract infections. Still, we believe it is an alterna-tive for infections caused by MDR and/or XDR pathogens in renal transplant patients, as other options are nephrotoxic.
  • article 1 Citação(ões) na Scopus
    Evaluation of loop-mediated isothermal amplification assay for detection of Clostridioides difficile infection: A prospective diagnostic performance study
    (2021) GIRA, Evelyne Santana; NOGUERA, Saidy Liceth Vasconez; ESPINOZA, Evelyn Patricia Sanchez; BEZERRA, Camila Loredana Pereira Alves Madeira; LINO, Fernando Molina; CORTES, Marina Farrel; SANTOS, Sania Alves dos; PARANHOS-BACCALA, Glaucia; PERDIGA, Lauro Vieira; COSTA, Silvia Figueiredo
    A novel Loop-mediated isothermal amplification (LAMP) assay, HiberGene's CD was evaluated with 82 unformed stools from patients suspected of C. difficile infection (CDI). Compared to glutamate dehy-drogenase (GDH) toxins A/B test (C.diff Quik Chek (R)), HiberGene's LAMP showed 100% of sensitivity and 95,8% of specificity; and compared to FilmArrayTM GI panel (R) (BioFire), a sensitivity of 81,2% and a specificity of 100%, with 96.38% of agreement.
  • article 6 Citação(ões) na Scopus
    Are mobile phones part of the chain of transmission of SARS- CoV-2 in hospital settings?
    (2021) ESPINOZA, Evelyn Patricia Sanchez; CORTES, Marina Farrel; NOGUERA, Saidy Vasconez; PAULA, Anderson Vicente de; GUIMARAES, Thais; BOAS, Lucy Santos Villas; PARK, Marcelo; SILVA, Cristina Carvalho da; MORALES, Ingra; NETO, Lauro Vieira Perdigao; TOZETTO-MENDOZA, Tania Regina; BOSZCZOWSKI, Icaro; SABINO, Ester Cerdeira; MENDES-CORREA, Maria Cassia; LEVIN, Anna Sara; COSTA, Silvia Figueiredo
    Mobile phones (MPs) have become an important work tool around the world including in hospitals. We evaluated whether SARS-CoV-2 can remain on the surface of MPs of first-line healthcare workers (HCW) and also the knowledge of HCWs about SARS-CoV-2 cross-transmission and conceptions on the virus survival on the MPs of HCWs. A crosssectional study was conducted in the COVID-19 Intensive Care Unit of a teaching hospital. An educational campaign was carried out on cross-transmission of SARS-CoV-2, and its permanence in fomites, in addition to the proper use and disinfection of MPs. Herewith an electronic questionnaire was applied including queried conceptions about hand hygiene and care with MP before and after the pandemic. The MPs were swabbed with a nylon FLOQ SwabTM, in an attempt to increase the recovery of SARS-CoV-2. All MP swab samples were subjected to SARS-CoV-2 RT-PCR; RT-PCR positive samples were subjected to viral culture in Vero cells (ATCC (R) CCL-81TM). Fifty-one MPs were swabbed and a questionnaire on hand hygiene and the use and disinfection of MP was applied after an educational campaign. Most HCWs increased adherence to hand hygiene and MP disinfection during the pandemic. Fifty-one MP swabs were collected and two were positive by RT-PCR (4%), with Cycle threshold (Ct ) values of 34-36, however, the cultures of these samples were negative. Although most HCWs believed in the importance of cross-transmission and increased adherence to hand hygiene and disinfection of MP during the pandemic, SARS-CoV-2 RNA was detected in MPs. Our results suggest the need for a universal policy in infection control guidelines on how to care for electronic devices in hospital settings.
  • article 4 Citação(ões) na Scopus
    Characterization of Severe Acute Respiratory Syndrome Coronavirus 2 Omicron Variant Shedding and Predictors of Viral Culture Positivity on Vaccinated Healthcare Workers With Mild Coronavirus Disease 2019
    (2022) LUNA-MUSCHI, Alessandra; NOGUERA, Saidy Vasconez; BORGES, Igor C.; V, Anderson De Paula; CORTES, Marina Farrel; LAROCCA, Carolina; MARI, Julia Ferreira; GUIMARAES, Lara Silva Pereira; TORRES, Pablo Munoz; SCACCIA, Nazareno; VILLAS-BOAS, Lucy S.; JR, Almir Ribeiro da Silva; ANDRADE, Pamela S.; TEIXEIRA, Juliana C.; ESCADAFAL, Camille; OLIVEIRA, Vitor Falcao de; TOZETTO-MENDOZA, Tania R.; MENDES-CORREA, Maria Cassia; LEVIN, Anna S.; SABINO, Ester C.; COSTA, Silvia F.
    We evaluated the duration of viral culture positivity compared to rapid antigen test (RAT) and real-time reverse-transcription polymerase chain reaction (RT-PCR) in mild Omicron infection. Vaccinated persons are potentially transmissible up to day 7. RAT and RT-PCR are predictors of viral culture positivity. In this prospective cohort of 30 vaccinated healthcare workers with mild Omicron variant infection, we evaluated viral culture, rapid antigen test (RAT), and real-time reverse-transcription polymerase chain reaction (RT-PCR) of respiratory samples at days 5, 7, 10, and 14. Viral culture was positive in 46% (11/24) and 20% (6/30) of samples at days 5 and 7, respectively. RAT and RT-PCR (Ct <= 35) showed 100% negative predictive value (NPV), with positive predictive values (PPVs) of 32% and 17%, respectively, for predicting viral culture positivity. A lower RT-PCR threshold (Ct <= 24) improved culture prediction (PPV = 39%; NPV = 100%). Vaccinated persons with mild Omicron infection are potentially transmissible up to day 7. RAT and RT-PCR might be useful tools for shortening the isolation period.
  • article 0 Citação(ões) na Scopus
    Multicenter Diagnostic Evaluation of OnSite COVID-19 Rapid Test (CTK Biotech) among Symptomatic Individuals in Brazil and the United Kingdom
    (2023) THOMPSON, Caitlin; TORRES, Pablo Munoz; KONTOGIANNI, Konstantina; BYRNE, Rachel; NOGUERA, Saidy Vasconez; LUNA-MUSCHI, Alessandra; MARCHI, Ana Paula; ANDRADE, Pamela S.; BARBOZA, Antonio dos Santos; NISHIKAWARA, Marli; BODY, Richard; VOS, Margaretha de; ESCADAFAL, Camille; ADAMS, Emily; COSTA, Silvia Figueiredo; CUBAS-ATIENZAR, Ana
    Evaluating rapid diagnostic tests in diverse populations is essential to improving diagnostic responses as it gives an indication of the accuracy in real-world scenarios. In the case of rapid diagnostic testing within this pandemic, lateral flow tests that meet the minimum requirements for sensitivity and specificity can play a key role in increasing testing capacity, allowing timely clinical management of those infected, and protecting health care systems. The COVID-19 pandemic has given rise to numerous commercially available antigen rapid diagnostic tests (Ag-RDTs). To generate and to share accurate and independent data with the global community requires multisite prospective diagnostic evaluations of Ag-RDTs. This report describes the clinical evaluation of the OnSite COVID-19 rapid test (CTK Biotech, CA, USA) in Brazil and the United Kingdom. A total of 496 paired nasopharyngeal (NP) swabs were collected from symptomatic health care workers at Hospital das Clinicas in Sao Paulo, Brazil, and 211 NP swabs were collected from symptomatic participants at a COVID-19 drive-through testing site in Liverpool, United Kingdom. Swabs were analyzed by Ag-RDT, and results were compared to quantitative reverse transcriptase PCR (RT-qPCR). The clinical sensitivity of the OnSite COVID-19 rapid test in Brazil was 90.3% (95% confidence interval [CI], 75.1 to 96.7%) and in the United Kingdom was 75.3% (95% CI, 64.6 to 83.6%). The clinical specificity in Brazil was 99.4% (95% CI, 98.1 to 99.8%) and in the United Kingdom was 95.5% (95% CI, 90.6 to 97.9%). Concurrently, analytical evaluation of the Ag-RDT was assessed using direct culture supernatant of SARS-CoV-2 strains from wild-type (WT), Alpha, Delta, Gamma, and Omicron lineages. This study provides comparative performance of an Ag-RDT across two different settings, geographical areas, and populations. Overall, the OnSite Ag-RDT demonstrated a lower clinical sensitivity than claimed by the manufacturer. The sensitivity and specificity from the Brazil study fulfilled the performance criteria determined by the World Health Organization, but the performance obtained from the UK study failed to do. Further evaluation of Ag-RDTs should include harmonized protocols between laboratories to facilitate comparison between settings.IMPORTANCE Evaluating rapid diagnostic tests in diverse populations is essential to improving diagnostic responses as it gives an indication of the accuracy in real-world scenarios. In the case of rapid diagnostic testing within this pandemic, lateral flow tests that meet the minimum requirements for sensitivity and specificity can play a key role in increasing testing capacity, allowing timely clinical management of those infected, and protecting health care systems. This is particularly valuable in settings where access to the test gold standard is often restricted.
  • article 2 Citação(ões) na Scopus
    Disinfection of 3D-printed protective face shield during COVID-19 pandemic
    (2021) NOGUERA, Saidy Vasconez; ESPINOZA, Evelyn Patricia Sanchez; CORTES, Marina Farrel; OSHIRO, Izabel Cristina Vilela; SPADAO, Fernanda de Sousa; BRANDAO, Laura Maria Brasileiro; BARROS, Ana Natiele da Silva; COSTA, Sibeli; ALMEIDA, Bianca Leal de; SORIANO, Paula Gemignani; SALLES, Alessandra Grassi; ESCORCIO, Mirian Elizabete Marques; BARRETTI, Cristina Madeira; BAPTISTA, Fernanda Spadotto; ALVARENGA, Glaura Souza; MARINHO, Igor; LETAIF, Leila Suemi Harima; LI, Ho Ye; BACCHI, Pedro; SANTOS, Ana Rubia Guedes dos; REGADAS, Lucas Borges; BRAGA, Carlos Eduardo Lima; ZSIGMOND, Fabio; SEGURADO, Aluisio Cotrim; GUIMARAES, Thais; LEVIN, Anna Sara; BERTOLDI, Cristiane Aun; CATALANI, Luiz Henrique; ZANCUL, Eduardo de Senzi; COSTA, Silvia Figueiredo
    This study assessed the disinfection using 70% ethanol; H2O2-quaternary ammonium salt mixture; 0.1% sodium hypochlorite and autoclaving of four 3D-printed face shields with different designs, visor materials; and visor thickness (0.5-0.75 mm). We also investigated their clinical suitability by applying a questionnaire to health workers (HW) who used them. Each type of disinfection was done 40 times on each type of mask without physical damage. In contrast, autoclaving led to appreciable damage.
  • article 1 Citação(ões) na Scopus
    Virulomic Analysis of Multidrug-Resistant Klebsiella pneumoniae Isolates and Experimental Virulence Model Using Danio rerio (Zebrafish)
    (2022) DUARTE, Edson Luiz Tarsia; RIZEK, Camila Fonseca; ESPINOZA, Evelyn Sanchez; MARCHI, Ana Paula; NOGUERA, Saidy Vasconez; CORTES, Marina Farrel; FERNANDES, Bianca H. Ventura; GUIMARAES, Thais; CARRILHO, Claudia M. D. de Maio; V, Lauro Perdigao Neto; TRINDADE, Priscila A.; COSTA, Silvia Figueiredo
    This study evaluates a possible correlation between multidrug-resistant Klebsiella pneumoniae strains and virulence markers in a Danio rerio (zebrafish) model. Whole-genome sequencing (WGS) was performed on 46 strains from three Brazilian hospitals. All of the isolates were colistin-resistant and harbored bla(KPC-2). Ten different sequence types (STs) were found; 63% belonged to CC258, 22% to ST340, and 11% to ST16. The virulence factors most frequently found were type 3 fimbriae, siderophores, capsule regulators, and RND efflux-pumps. Six strains were selected for a time-kill experiment in zebrafish embryos: infection by ST16 was associated with a significantly higher mortality rate when compared to non-ST16 strains (52% vs. 29%, p = 0.002). Among the STs, the distribution of virulence factors did not differ significantly except for ST23, which harbored a greater variety of factors than other STs but was not related to a higher mortality rate in zebrafish. Although several virulence factors are described in K. pneumoniae, our study found ST16 to be the only significant predictor of a virulent phenotype in an animal model. Further research is needed to fully understand the correlation between virulence and sequence types.
  • article 13 Citação(ões) na Scopus
    Decontamination and re-use of surgical masks and respirators during the COVID-19 pandemic
    (2021) CORTES, Marina Farrel; ESPINOZA, Evelyn Patricia Sanchez; NOGUERA, Saidy Liceth Vasconez; SILVA, Aline Alves; MEDEIROS, Marion Elke Sielfeld Araya de; BOAS, Lucy Santos Villas; FERREIRA, Noely Evangelista; TOZETTO-MENDOZA, Tania Regina; MORAIS, Fernando Goncalves; QUEIROZ, Rayana Santiago de; PROENCA, Adriana Coracini Tonacio de; GUIMARAES, Thais; GUEDES, Ana Rubia; LETAIF, Leila Suemi Harima; MONTAL, Amanda Cardoso; MENDES-CORREA, Maria Cassia; JOHN, Vanderley M.; LEVIN, Anna S.; COSTA, Silvia Figueiredo
    Objectives: The coronavirus disease 2019 pandemic increased global demand for personal protective equipment (PPE) and resulted in shortages. The study evaluated the re-use of surgical masks and respirators by analysing their performance and safety before and after reprocessing using the following methods: oven, thermal drying, autoclave, and hydrogen peroxide plasma vapour. Methods: In total, 45 surgical masks and 69 respirators were decontaminated. Visual integrity, air permeability, burst resistance, pressure differential and particulate filtration efficiency of new and decontaminated surgical masks and respirators were evaluated. In addition, 14 used respirators were analysed after work shifts before and after decontamination using reverse transcription polymerase chain reaction (RT-PCR) and viral culturing. Finally, reprocessed respirators were evaluated by users in terms of functionality and comfort. Results: Oven decontamination (75 degrees C for 45 min) was found to be the simplest decontamination method. Physical and filtration assays indicated that all reprocessing methods were safe after one cycle. Oven decontamination maintained the characteristics of surgical masks and respirators for at least five reprocessing cycles. Viral RNA was detected by RT-PCR in two of the 14 used respirators. Four respirators submitted to viral culture were PCR-negative and culture-negative. Reprocessed respirators used in work shifts were evaluated positively by users, even after three decontamination cycles. Conclusion: Oven decontamination is a safe method for reprocessing surgical masks and respirators for at least five cycles, and is feasible in the hospital setting. (C) 2020 Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
  • article 1 Citação(ões) na Scopus
    Chlorhexidine susceptibility and Eagle effect in planktonic cells and biofilm of nosocomial isolates
    (2023) MARCHI, Ana Paula; CORTES, Marina Farrel; NOGUERA, Saidy Vasconez; ROSSI, Flavia; LEVIN, Anna Sara; COSTA, Silvia Figueiredo; NETO, Lauro Vieira Perdigao
    The aim of this study is to evaluate the chlorhexidine gluconate (CHG) susceptibility in both planktonic cells and biofilm of 32 Gram-negative (Gn) and 6 Gram-positive (Gp) isolates by minimal inhibitory concentration (2-256 mu g/mL for Gn and 2-32 mu g/mL for Gp), minimal bactericidal concentration (4-256 mu g/mL for Gn and 2-32 mu g/mL for Gp) in planktonic cells, and minimal biofilm elimination concentration (128 >= 16,384 mu g/mL in Gn and 32 >= 16,384 mu g/mL in Gp) in biofilm environment. Our study showed that Gn isolates have higher minimal concentrations than Gp and bacteria in biofilms are more tolerant than planktonic ones. No correlation between MBC or MBEC and biofilm formation was statistically confirmed. The Eagle effect, previously described for antimicrobials and antifungals, was evidenced in this work for CHG, an antiseptic. Besides that, the phenomenon was described in 23/38 isolates (60.5%), raising minimal concentration up to >= 16,384 mu g/mL. Our study showed that clinical isolates have a high ability to form biofilm allowing them to tolerate CHG concentrations as high as the ones used in clinical practice. Therefore, attention should be given to the occurrence of this phenomenon to avoid false susceptibility results.