Resumo
BACKGROUND: Low-cost portable infrared cameras are increasingly used for health assessments, especially for investigating the skin temperature of the whole body. However, some of these devices have not yet been tested for agreement with high-resolution cameras. Therefore, the objective of this study was to test the agreement of FLIR C5, a portable infrared thermographic camera, compared to the FLIR T650sc, a high-quality and high-resolution thermographic device, for detecting thermal asymmetry between both sides of the body of patients with motor sequelae after stroke. MATERIALS AND METHODS: This is an observational and cross-sectional study conducted in a physical rehabilitation facility with 14 patients with stroke sequelae. Participants had their temperature simultaneously measured by FLIR T650sc and FLIR C5 infrared thermography cameras and analyzed with the software FLIR Tools®. The temperature difference of each ROI measured by both cameras was compared with Lin's Concordance Correlation Coefficient (rho or ρc) and Bland Altman the limits of agreement (LOA). RESULTS: the temperatures measured by FLIR C5 were lower than those measured by FLIR T650sc, regardless of the region of interest or side (-0.65, SD 1.44). We observed that the general concordance was classified as adequate to excellent (ρc=0.859; 95%CI 0.817-0.901; p<0.001) and that the forearm and leg in the posterior view presented the sites with the best associations between the temperature readings of FLIR C5 and FLIR T650sc. CONCLUSIONS: The temperature asymmetry usually found among patients with stroke sequelae may be assessed by the portable infrared thermographic camera FLIR C5, given its suitable concordance with FLIR T650sc.
Palavras-chave
affordable infrared cameras, cutaneous temperature, mobile thermography, stroke, Thermography
Referências
  1. Jiang LJ, Ng EYK, Yeo ACB, Wu S, Pan F, Yau WY, Et al., A perspective on medical infrared imaging, J Med Eng Technol, 29, 6, pp. 257-267, (2005)
  2. Meola C., Infrared thermography in the architectural field, Sci World J, 2013, (2013)
  3. Rekant SI, Lyons MA, Pacheco JM, Arzt J, Rodriguez LL., Veterinary applications of infrared thermography, Am J Vet Res, 77, 1, pp. 98-107, (2016)
  4. Casas-Alvarado A, Mota-Rojas D, Hernandez-Avalos I, Mora-Medina P, Olmos-Hernandez A, Verduzco-Mendoza A, Et al., Advances in infrared thermography: Surgical aspects, vascular changes, and pain monitoring in veterinary medicine, J Therm Biol, 92, (2020)
  5. Tattersall GJ., Infrared thermography: A non-invasive window into thermal physiology, Comp Biochem Physiol Part A Mol Integr Physiol, 202, pp. 78-98, (2016)
  6. Szentkuti A, Skala Kavanagh H, Grazio S., Infrared thermography and image analysis for biomedical use, Period Biol, 113, 4, pp. 385-392, (2011)
  7. Fernandez-Cuevas I, Marins JCB, Lastras JA, Carmona PMG, Cano SP, Garcia-Concepcion MA, Et al., Classification of factors influencing the use of infrared thermography in humans: A review, Infrared Phys Technol, 71, pp. 28-55, (2015)
  8. Alfieri FM, da Silva Dias C, Vargas e Silva NC, Santos ACA, Battistella LR., Comparison of iOS smartphone-attached infrared camera and conventional FLIR camera for human temperature measurement: an agreement study, Thermol Int [Internet], 30, 3, pp. 91-96, (2020)
  9. Alfieri FM, Santos ACA, Dias C da S, Battistella LR., Using iOS Smartphone-attached infrared camera for detecting regional skin temperature symmetry, Thermol Int, 31, 2, pp. 47-52, (2021)
  10. Ammer K., Employment of FLIR ONE Infrared Cameras in medicine -A literature overview, Thermol Int, 30, pp. 128-145, (2020)
  11. Topalidou A, Markarian G, Downe S., Thermal imaging of the fetus: An empirical feasibility study, PLoS One, 15, 7, (2020)
  12. Rahbek O, Husum H-C, Fridberg M, Ghaffari A, Kold S., Intrarater reliability of digital thermography in detecting pin site infection: a proof of concept study, Strateg Trauma Limb Reconstr, 16, 1, (2021)
  13. Ring EFJ, Ammer K., The technique of infrared imaging in medicine, Thermol Int, 10, 1, pp. 7-14, (2000)
  14. Marins JCB, Fernandes AA, Cano SP, Moreira DG, da Silva FS, Costa CMA, Et al., Thermal body patterns for healthy Brazilian adults (male and female), J Therm Biol, 42, pp. 1-8, (2014)
  15. Alfieri FM, Battistella LR., Body temperature of healthy men evaluated by thermography: A study of reproducibility, Technol Heal care, 26, 3, pp. 559-564, (2018)
  16. Giavarina D., Understanding Bland Altman analysis, Biochemmedica, 25, 2, pp. 141-151, (2015)
  17. Lawrence I, Lin K., A concordance correlation coefficient to evaluate reproducibility, Biometrics, pp. 255-268, (1989)
  18. McBride GB., A proposal for strength-of-agreement criteria for Lin's concordance correlation coefficient, NIWA client Rep HAM2005-062, 45, pp. 307-310, (2005)
  19. Barthels D, Das H., Current advances in ischemic stroke research and therapies, Biochim Biophys Acta (BBA)-Molecular Basis Dis, 1866, 4, (2020)
  20. Katan M, Luft A., Global burden of stroke, Seminars in neurology, pp. 208-211, (2018)
  21. Wanklyn P, Ilsley DW, Greenstein D, Hampton IF, Roper TA, Kester RC, Et al., The cold hemiplegic arm, Stroke, 25, 9, pp. 1765-1770, (1994)
  22. Fujita K, Yamamoto T, Kamezaki T, Matsumura A., Efficacy of keishibukuryogan, a traditional Japanese herbal medicine, in treating cold sensation and numbness after stroke: clinical improvement and skin temperature normalization in 22 stroke patients, Neurol Med Chir (Tokyo), 50, 1, pp. 1-6, (2010)
  23. Alfieri FM, Massaro AR, Filippo TR, Portes LA, Battistella LR., Evaluation of body temperature in individuals with stroke, NeuroRehabilitation, 40, 1, pp. 119-128, (2017)
  24. da Silva Dias C, Alfieri FM, dos Santos ACA, Battistella LR., Body temperature and esthesia in individuals with stroke, Sci Rep [Internet], 11, 1, (2021)
  25. Dias C da S, Alfieri FM, Santos ACA, Battistella LR., Whole-body thermographic assessment of patients with stroke sequelae who report temperature differences between the sides, Thermol Int, 32, 1, pp. 14-19, (2022)
  26. Feldman F, Nickoloff EL., Normal thermographic standards for the cervical spine and upper extremities, Skeletal Radiol, 12, 4, pp. 235-249, (1984)
  27. Uematsu S, Jankel WR, Edwin DH, Kim W, Kozikowski J, Rosenbaum A, Et al., Quantification of thermal asymmetry. Part 2: Application in low-back pain and sciatica, J Neurosurg, 69, 4, pp. 556-561, (1988)
  28. Thomas D, Cullum D, Siahamis G, Langlois S., Infrared thermographic imaging, magnetic resonance imaging, CT scan and myelography in low back pain, Rheumatology, 29, 4, pp. 268-273, (1990)
  29. Campbell I., Body temperature and its regulation, Anaesth Intensive Care Med, 9, 6, pp. 259-263, (2008)
  30. Alfieri FM, Dias C da S, Santos ACA, Battistella LR., Acute effect of robotic therapy (G-EO SystemTM) on the Lower Limb Temperature Distribution of a Patient with Stroke Sequelae, Case Rep Neurol Med, (2019)