Sensibility of the ear after otoplasty
Nenhuma Miniatura disponível
Citações na Scopus
0
Tipo de produção
bookPart
Data de publicação
2013
Título da Revista
ISSN da Revista
Título do Volume
Editora
SPRINGER BERLIN HEIDELBERG
Autores
Citação
Coltro, P. S.; Ferreira, M. C.. Sensibility of the ear after otoplasty. In: . ADVANCED COSMETIC OTOPLASTY: ART, SCIENCE, AND NEW CLINICAL TECHNIQUES: SPRINGER BERLIN HEIDELBERG, 2013. p.557-564.
Resumo
Assessment of cutaneous tactile sensibility may be carried out by some neurosensory tests, based on the knowledge of skin innervation Dellon (Ann Plast Surg 51(1):6–9, 2003). The group A-beta nerve fibers are responsible for conducting touch stimuli including both those from slow- and fast-adaptation sensory receptors. The slow-adaptative fibers conduct pressure perception, constant touch, and texture, and their skin receptors are the Merkel and Ruffini cells. The fast-adaptative fibers provide motion and vibration perception, and their cutaneous receptors are the Meissner and Pacini cells. The authors report the results of their study of the sensibility of the ear preoperatively and postoperatively. © Springer-Verlag Berlin Heidelberg 2013.
Palavras-chave
Referências
- Janis, J.E., Rohrich, R.J., Gutowski, K.A., Otoplasty (2005) Plast Reconstr Surg, 115 (4), pp. 60e-72e
- Hoehn, J.G., Ashruf, S., Otoplasty: Sequencing the operation for improved results (2005) Plast Reconstr Surg, 115 (1), pp. 5e-16e
- Kelley, P., Hollier, L., Stal, S., Otoplasty: Evaluation, technique, and review (2003) J Craniofac Surg, 14 (5), pp. 643-653
- Peker, F., Celiköz, B., Otoplasty: Anterior scoring and posterior rolling technique in adults (2002) Aesthetic Plast Surg, 26 (4), pp. 267-273
- Dellon, A.L., Invited discussion: Sensibility of the breast following reduction mammaplasty (2003) Ann Plast Surg, 51 (1), pp. 6-9
- Carvalho, V.F., Ferreira, M.C., Vieira, S.A., Ueda, T., Cutaneous sensibility threshold in the feet of diabetic patients with pressure specified sensory device: An assessment of the neuropathy (2009) Rev Assoc Med Bras, 55 (1), pp. 29-34
- Dellon, A.L., (2000) Evaluation of sensibility and re-education of sensation in the hand, , Baltimore: Lippincott Williams & Wilkins
- Dellon, A.L., (2000) Somatosensory testing and rehabilitation, , Baltimore: Lippincott Williams & Wilkins
- Dellon, E.S., Mourey, M.S., Dellon, A.L., Human pressure perception values of constant and moving one and two-point discrimination (1992) Plast Reconstr Surg, 90 (1), pp. 112-117
- Dellon, E.S., Crone, S., Mourey, R., Dellon, A.L., Comparison of the Semmes-Weinstein mono filaments with the pressure specified sensory device (1993) Restor Neurol Neurosci, 5 (5), pp. 323-326
- Ferreira, M.C., Costa, M.P., Cunha, M.S., Sakae, E., Fels, K.W., Sensibility of the breast after reduction mammaplasty (2003) Ann Plast Surg, 51 (1), pp. 1-5
- Ferreira, M.C., Rodrigues, L., Fels, K.W., New method for evaluation of cutaneous sensibility in diabetic feet: Preliminary report (2004) Rev Hosp Clin Fac Med Sao Paulo, 59 (5), pp. 286-290
- Fels, K.W., Cunha, M.S., Sturtz, G.P., Gemperli, R., Ferreira, M.C., Evaluation of cutaneous abdominal wall sensibility after abdominoplasty (2005) Aesthetic Plast Surg, 29 (2), pp. 78-82
- Fogaça, W.C., Ferreira, M.C., Dellon, A.L., Infraorbital nerve injury associated with zygoma fractures: Documentation with neurosensory testing (2004) Plast Reconstr Surg, 113 (3), pp. 834-838
- Fogaça, W.C., Sturtz, G.P., Surjan, R.C., Ferreira, M.C., Evaluation of cutaneous sensibility on infraorbital nerve area (2005) J Craniofac Surg, 16 (6), pp. 953-956
- Coltro, P.S., Alves, H.R., Gallafrio, S.T., Busnardo, F.F., Ferreira, M.C., Sensibility of ear after otoplasty (2011) Ann Plast Surg, 68 (2), pp. 120-124
- Yarnitsky, D., Quantitative sensory testing (1997) Muscle Nerve, 20 (2), pp. 198-204
- Dellon, A.L., From there to here: A personal viewpoint after three decades of neuropathy research (2006) Clin Podiatr Med Surg, 23 (3), pp. 497-508
- Soomekh, D., Quantitative sensory testing (2006) Clin Podiatr Med Surg, 23 (3), pp. 545-557
- Mofid, M.M., Dellon, A.L., Elias, J.J., Nahabedian, M.Y., Quantitation of breast sensibility following reduction mammaplasty: A comparison of inferior and medial pedicle techniques (2002) Plast Reconstr Surg, 109 (7), pp. 2283-2288
- Grime, P.D., A pilot study to determine the potential application of the pressure specified sensory device in the maxillofacial region (1996) Br J Oral Maxillofac Surg, 34 (6), pp. 500-503
- Levin, S., Pearsall, G., Ruderman, R.J., Von Frey's method of measuring pressure sensibility in the hand: An engineering analysis of the Weinstein-Semmes pressure aesthesiometer (1978) J Hand Surg Am, 3 (3), pp. 211-216
- Malgrange, D., Richard, J.L., Leymarie, F., Screening diabetic patients at risk for foot ulceration. A multi-centre hospital-based study in France (2003) Diabetes Metab, 29 (3), pp. 261-268
- Dellon, A.L., Testing for facial sensibility (1991) Plast Reconstr Surg, 87 (6), pp. 1140-1141
- Posnick, J.C., Grossman, J.A., Facial sensibility testing: A clinical update (2000) Plast Reconstr Surg, 106 (4), pp. 892-894
- Dellon, A.L., The vibrometer (1983) Plast Reconstr Surg, 71 (3), pp. 427-431
- Posnick, J.C., Zimbler, A.G., Grossman, J.A., Normal cutaneous sensibility of the face (1990) Plast Reconstr Surg, 86 (3), pp. 429-433
- Costas, P.D., Heatley, G., Seckel, B.R., Normal sensation of the human face and neck (1994) Plast Reconstr Surg, 93 (6), pp. 1141-1145